EDGE-4 Managed Air-cooled MDC

By design
Specifically designed for housing localised ‘Edge’ computing either as a standalone cabinet or bayed together in a dedicated room. The EDGE-4 is configured with its own automated directional airflow exhaust ducting system which is capable of handling, distributing and removing high heat loads generated by multiple high-performance servers and other IT equipment in an energy efficient and controlled way.
Saves money by redirecting hot air away from ambient room temperatures thereby reducing air conditioning usage. Heat can be reclaimed in winter months and supply free heating when required.
Available in Q3

Rapid deployment Micro Data Center

Rapid deployment Micro Data Center
Simple ‘plug and play’ EDGE-4 solution is supplied pre-configured from the factory with built in intelligence and an energy efficient air-cooling system for effortless installation and customer convenience.
Peace of mind is provided by an on board environmental and optional security monitoring system. Real time alarms and alerts which can be viewed via the WebUI will notify authorised personnel via email alarms relating to any issues with the cabinet.
Meaning you know what’s going on and can monitor who’s coming and going 24/7.
Range

The EDGE-4 is available in two heights - 36U and 42U and one width 310.5”/800mm and one depth 47”.25/1200mm.
The in-built automated ducting feature perfectly compliments the cabinet design and performance, which includes high airflow front door and air sealed side and rear doors – creating an optimised energy efficient cooling system.
Heavy duty castors and levelling feet make siting and deployment easier, once positioned, the cabinet can be levelled, which is especially useful on uneven floors.
The plinth system allows easy access for cabling to pass underneath, once commissioned, plinth panels complete the look.
How it works


Another massive cost saving is made by reducing the frequency air-conditioning is used in summer months by redirecting hot air away from the working environment. Also, heat can be reclaimed in winter months and supply free heating when required.
The automated exhaust air ducting system is capable of removing and redistributing high heat loads generated by servers and other IT equipment in an energy efficient and controlled way.




By incorporating EC fan technology means an immediate energy reduction compared to standard AC or DC fans. The EDGE Management System has onboard EC fan control which enables the fans to ramp up and down in speed responding to the temperature within the enclosure – meaning only the necessary amount of power is used to maintain the ideal operating temperature.

Expelling hot air to atmosphere and saving air-conditioning energy or heat recovery and saving on heating bills = WIN-WIN!
'EDGE PACK' options
Further peace of mind and security is at hand with our state-of-the-art EDGE-PACK options in which USystems fully configure the original specification enclosure to include one or more of the following systems: